ethiopian standard of concrete

Hollow Concrete Block - Ethiopian Construction

4. The production of Hollow Concrete Blocks. a Aggregates, i.e. Sand, Gravel, Red Ash: should be clean, stored separatly close to the mixing plant. All aggregates used for production have to be approved by an. independant concrete labatory! b Water: mustbe clean and free of unpurifications

Get PriceEmail contact

ethiopian standard of concrete - prodeoplanner

Ethiopian Standards may be obtained from the Head Office of the Standards Agency Ethiopian , is the national standards body of Ethiopia establishedin 2010 based on regulation No 193/2010ESA is established due to the restructuring of Quality and Standards Authority of Ethiopia (QSAE) which was established in 1998 , TC 36 Concrete.

Get PriceEmail contact

Specification - Ethiopian Construction

Portland cement shall comply with the requirements of AASHTO M 85 or equivalent grade in accordance with ISO or Ethiopian Standards. Road lime shall comply with the requirements of AASHTO M 216 (lime for stabilization). One filler shall be used throughout in order to minimize co lour differences in the surface. (f) Hydrophillic aggregates

Get PriceEmail contact

What is the ratio of c 5 concrete in ethiopian standard

What is the ratio of c 5 concrete in ethiopian standard Products. As a leading global manufacturer of crushing, grinding and mining equipments, we offer advanced, reasonable solutions for any size-reduction requirements including, What is the ratio of c 5 concrete in ethiopian standard, quarry, aggregate, and different kinds of minerals.

Get PriceEmail contact

EBCS-1 I - Construction in ethiopia, ethiopian ...

ETHIOPIAN BUILDING ~-CODE STANDARD FOR LOADING (c) Adequate supervision and quality control is provided during execution of the work, i.e. in design offices, factories, plants arid on site. . (d) The construction materials and products are used as specified in this Code or in ENV s EBCS

Get PriceEmail contact

Properties of Different Grades of Concrete Using Mix ...

characteristics of the concrete required are incorporated in the design procedure. 2.2 Grade Designation According to Yunusa (2011) every concrete has its strength in N/mm2 when subject to test after 28 days of curing in any medium. The choice of concrete grade, depends on the purpose and usage as follows: Table 1: Concrete Grade Designation

Get PriceEmail contact

Conventional grade C20, C25 and C30 concrete mix ratio ...

17/01/2018  1, meet the strength grade of concrete design. 2, meet the concrete peaceability. 3, meet the durability of the use of concrete. 4, meet the above conditions to save cement and reduce the cost of concrete. The strength of concrete is divided into twelve grades, such as C7.5, C10, C15, C20, C25, C30, C35, C40, C45, C50, C55, C60 and so on.

Get PriceEmail contact

(PDF) Ethiopian Standard ES-EBCS 11 CODE OF PRACTICE

6.1.4 Performance tests and adjustments (1) Appropriate sections of the plant shall be run and all necessary adjustments of valves, dampers and controls should be made to fulfill the function for which it has been designed, .g room temperature and humidity to be maintained, air quantity to be handled, etc. Reference can be made to an acceptable standard such as ASHRAE Standard 111. (2) The contractor shall ensure that all performance test requirements are achieved and the plant

Get PriceEmail contact

Standards and Quality in Ethiopia - Ethioconstruction

safety, taste, conforming to standards, uniformity. The definition found in the Oxford business dictionary is: ðdegree of goodness or worth; ðgeneral excellence; ðunbreakable; ðhigh social standard. Some Ethiopian enterprises define quality as: ðmaintaining requisite standards; ðdefect-free product; ðsystematic inspection of products.

Get PriceEmail contact

design example of six storey building

Indian Standards. • Comments and feedbacks may please be forwarded to: Prof. Sudhir K Jain, Dept. of Civil Engineering, IIT Kanpur, Kanpur 208016, email: [email protected] . Design Example of a Building IITK-GSDMA-EQ26-V3.0 Page 3 Example — Seismic Analysis and Design of a Six Storey Building Problem Statement: A six storey building for a commercial complex has plan dimensions as shown in ...

Get PriceEmail contact

Ethiopia Standards Agency Adopts ASTM Concrete

Ethiopian Standards Agency Adopts ASTM Concrete Standards. The Ethiopian Standards Agency has adopted several ASTM International standards for building construction over the past year. ESA and ASTM signed a memorandum of understanding in 2005. Established in 1970, the Ethiopian Standards Agency (formerly the Quality and Standards Authority of Ethiopia) is the national standards body of ...

Get PriceEmail contact

Ethiopia Standards Agency Adopts Several ASTM ...

The Ethiopian Standards Agency (EX Quality and Standards Authority of Ethiopia) has adopted several ASTM International standards for building construction over the past year. The Ethiopian Standards Agency (ESA) and ASTM signed a memorandum of understanding (MOU) in 2005.Established in 1970, the Ethiopian Standards Agency (formerly the Quality and Standards

Get PriceEmail contact

What is the ratio of c 5 concrete in ethiopian standard

What is the ratio of c 5 concrete in ethiopian standard Products. As a leading global manufacturer of crushing, grinding and mining equipments, we offer advanced, reasonable solutions for any size-reduction requirements including, What is the ratio of c 5 concrete in ethiopian standard, quarry, aggregate, and different kinds of minerals.

Get PriceEmail contact

Construction in Ethiopia - HDM

Even though concrete results are not yet obtained. Earthquake safety Since the Great Rift Valley pass through Ethiopia, some cities are categorised under the seismic zone of Ethiopia. Now days due to this, every building is designed consid-ering the expected maximum earthquake loads. According to the Ethiopian standard code of practise, comparisons

Get PriceEmail contact

Standards and Quality in Ethiopia - Ethioconstruction

Standards and Quality in Ethiopia Addis Ababa, Ethiopia March 2004 Published by: Ethiopian Business Development Services Network (EBDSN) P.O.Box 11133 Addis Ababa, Ethiopia In collaboration with: Quality and Standards Authority of Ethiopia (QSAE), Ethio-German TVET Programme, Ethio-German Micro and Small Enterprises Development Project (GTZ) On ...

Get PriceEmail contact

Properties of Different Grades of Concrete Using Mix ...

prescribes a standard concrete mix ratio that he thinks will produce the required concrete. He may also indicate the type and size of aggregate to be used. The Builder/site engineer prepares the mixes based on the ratio that has been prescribed. 2.1.3 Designed Mixes In these mixes the performance of the concrete is specified by the designer but the mix proportions are determined by the ...

Get PriceEmail contact

Ethiopian Standards General Information (Quality ...

Ethiopian Standards (ESs) provide industry and users with the framework for economies of design, greater product and service quality, more inter-operability, and better production and delivery efficiency. At the same time, Ethiopian Standards also promote an improved quality of life by contributing to safety, human health and the protection of the environment. Level and type of standards. The ...

Get PriceEmail contact

THE NEED FOR STANDARDIZATION OF AGGREGATES FOR CONCRETE

standard requirements and concrete compressive strength data’s obtained using different aggregate qualities are evaluated. Based on the findings, conclusions are drawn and recommendations are forwarded. Keywords Aggregates, Alkali-silica reaction, Basalt, Cement, Concrete, Pumice, Rock, Scoria . 2 INTRODUCTION Concrete is a versatile and most popular construction material in the world. It is ...

Get PriceEmail contact

(PDF) Comparison of IS, BS and ACI Methods of Concrete

ABSTRACT: In this paper a comparison of mix design procedures of IS method - Concrete mix proportioning guidelines (Bureau of Indian Standards-I.S.10262-2009), BS method (

Get PriceEmail contact

Ready-mix concrete - Wikipedia

Ready-Mix Concrete is concrete that is manufactured in a batch plant, according to a set engineered mix design. Ready-mix concrete is normally delivered in two ways. First is the barrel truck or in–transit mixers. This type of truck delivers concrete in a plastic state to the site. Second is the volumetric concrete mixer. This delivers the ready mix in a dry state and then mixes the concrete ...

Get PriceEmail contact

Ethiopia Standards Agency Adopts ASTM Concrete

Ethiopian Standards Agency Adopts ASTM Concrete Standards. The Ethiopian Standards Agency has adopted several ASTM International standards for building construction over the past year. ESA and ASTM signed a memorandum of understanding in 2005. Established in 1970, the Ethiopian Standards Agency (formerly the Quality and Standards Authority of Ethiopia) is the national standards body of ...

Get PriceEmail contact

Ethiopia Standards Agency Adopts Several ASTM ...

The Ethiopian Standards Agency (EX Quality and Standards Authority of Ethiopia) has adopted several ASTM International standards for building construction over the past year. The Ethiopian Standards Agency (ESA) and ASTM signed a memorandum of understanding (MOU) in 2005.Established in 1970, the Ethiopian Standards Agency (formerly the Quality and Standards

Get PriceEmail contact

Construction in Ethiopia - HDM

Even though concrete results are not yet obtained. Earthquake safety Since the Great Rift Valley pass through Ethiopia, some cities are categorised under the seismic zone of Ethiopia. Now days due to this, every building is designed consid-ering the expected maximum earthquake loads. According to the Ethiopian standard code of practise, comparisons

Get PriceEmail contact

Standards and Quality in Ethiopia - Ethioconstruction

Standards and Quality in Ethiopia Addis Ababa, Ethiopia March 2004 Published by: Ethiopian Business Development Services Network (EBDSN) P.O.Box 11133 Addis Ababa, Ethiopia In collaboration with: Quality and Standards Authority of Ethiopia (QSAE), Ethio-German TVET Programme, Ethio-German Micro and Small Enterprises Development Project (GTZ) On ...

Get PriceEmail contact

Design Method of Reinforced Concrete Shear Wall Using EBCS

KEYWORDS-concrete shear wall, Ethiopian building code standard (EBCS), lateral loads, moment of inertia, stress integration techniques. I. INTRODUCTION Shear walls are deep relatively thin vertically reinforced concrete beams .They are commonly used in the structures to resist the effects of gravity loads and storey shears. Shear walls are ...

Get PriceEmail contact

Ethiopian Standards General Information (Quality ...

Ethiopian Standards (ESs) provide industry and users with the framework for economies of design, greater product and service quality, more inter-operability, and better production and delivery efficiency. At the same time, Ethiopian Standards also promote an improved quality of life by contributing to safety, human health and the protection of the environment. Level and type of standards. The ...

Get PriceEmail contact

Quality control of concrete - SlideShare

20/02/2015  So, in order to achieve a quality and a durable building structure, maintaining the quality and standard of concrete is paramount. Quality is perceived differently by different people. Yet, everyone understands what is meant by “quality”. In a manufactured product, the customer as a user recognizes the quality of fit, finish, appearance, function, and performance. The quality of service ...

Get PriceEmail contact

Ready-mix concrete - Wikipedia

In the UK, ready-mixed concrete is specified either informally, by constituent weight or volume (1-2-4 or 1-3-6 being common mixes) or using the formal specification standards of the European standard EN 206+ A1, which is supplemented in the UK by BS 8500. This allows the customer to specify what the concrete has to be able to withstand in terms of ground conditions, exposure, and strength ...

Get PriceEmail contact

IS 2572: Construction of hollow and solid concrete block ...

Name of Standards Organization: Bureau of Indian Standards (BIS) Division Name: ... IS 2572 Title of Legally Binding Document: Construction of hollow and solid concrete block masonry - Code of practice Number of Amendments: Equivalence: Superceding: Superceded by: LEGALLY BINDING DOCUMENT Step Out From the Old to the New--Jawaharlal Nehru Invent a new India using knowledge. -

Get PriceEmail contact

EN 1992-1-1: Eurocode 2: Design of concrete structures ...

EUROPEAN STANDARD NORME EUROPEENNE EUROpAISCHE NORM ICS 91.010.30; 91.080.40 EN 1992-1-1 December 2004 Incorporating corrigenda January 2008 and November 2010 Supersedes ENV 1992-1-1 :1991, ENV 1992-1-3:1994, ENV 1992-1-4:1994, ENV 1992-1-5:1994, ENV 1992-1 6:1994, ENV 1992-3:1998 English version Eurocode 2: Design of concrete structures -Part 1-1 :

Get PriceEmail contact